Craniofacial Trauma and Intraocular Surgical Implants

10.4274/eajem.galenos.2021.04880

  • Sunny Chi Lik Au
  • Simon Tak Chuen Ko

Received Date: 02.01.2020 Accepted Date: 14.05.2020 Eurasian J Emerg Med 2021;20(4):287-288

Keywords: Eye, glaucoma, glaucoma drainage implant, eye injuries, eye foreign bodies

Introduction

Surgical implants are evolving and trending towards a smaller size to facilitate minimally invasive surgery. However, without adequate knowledge, they could be misinterpreted as harmful foreign bodies from trauma.


Case Report

A 34-year-old male construction site worker suffered from right eye blunt injury while hammering metals, and hit by a metal bar over his right head. He remained conscious without any nausea or dizziness, but attended the emergency department hours later for right eye pain. Applying latanoprost eye drop daily, he volunteered history of right eye uveitic glaucoma with glaucoma implant surgery. The ophthalmologist’s record mentioned an Ex-PRESS (excessive pressure regulating shunt system) shunt (Alcon Laboratories, Fort Worth, Texas, USA) was implanted and was compatible to magnetic resonance imaging (MRI) (1).

Visual acuities were Snellen decimal 0.1 and 0.8, whereas intraocular pressures (IOP) were 11 and 17 mmHg over right and left eye respectively. Right pupil was irregular with relative afferent pupillary defect. Slit lamp examination found a shiny metal over the superotemporal quadrant of the right eye (Figure 1), plugged by the iris adhering to cornea. There was conjunctival scarring, but no penetrating wounds, subconjunctival haemorrhage or hyphaema. Dilated fundus examination revealed glaucomatous changes without any retinal haemorrhage, commotio retinae, detachment nor rupture. Left eye was unremarkable. Computed tomography scanned for head injury highlighted the hyperdense implant inside the right eye (Figure 2), but no other intraocular foreign bodies nor fracture and intracranial haemorrhage.


Discussion

Head computed tomography is often scanned for head injury cases, but clinical correlation is essential in case of intraocular surgical implants, particularly their radiological imaging compatibility. Uveitic glaucoma arises from chronic uveitis with persistent elevated IOP (2). In refractory cases that failed pharmacological and traditional trabeculectomy surgery, glaucoma drainage device is the ultimate choice (3). Newer and smaller implants are evolving including the non-valved Baerveldt, valved Ahmed implant and Ex-PRESS. Among them, Ex-PRESS is the smallest (<3 mm), and the only metallic implant, made of stainless steel, giving its shiny appearance (4). Implanted patient is safe to undergo MRI without disturbing the implant (5).

Normally, we only see the tubular tip end of Ex-PRESS, whereas in our case, it has inferiorly subluxed, but held by the iris sticking it to the cornea. Ophthalmologists were consulted for assessment of the intraocular implant after the trauma, and they offered watch-and-wait conservative treatment with close monitoring of any subsequent rise in IOP. Repair surgery was not indicated unless uncontrollable IOP.


Conclusion

Intraocular implants are advancing, and smaller in size. This case helps emergency physicians to understand more on differentiating a surgical implant from an exogenous foreign body injury.

Ethics

Informed Consent: Informed consent was obtained from the patient.

Peer-review: Externally peer-reviewed.

Authorship Contributions

Surgical and Medical Practices: S.C.L.A., S.T.C.K., Concept: S.C.L.A., Design: S.C.L.A., Data Collection and/or Processing: S.C.L.A., Analysis and/or Interpretation: S.C.L.A., Literature Search: S.C.L.A., Writing: S.C.L.A., S.T.C.K.

Conflict of Interest: No conflict of interest was declared by the authors.

Financial Disclosure: The authors declared that this study received no financial support.


Images

  1. Chan JE, Netland PA. EX-PRESS glaucoma filtration device: efficacy, safety, and predictability. Med Devices (Auckl). 2015;8:381-8.
  2. Kalogeropoulos D, Sung VC. Pathogenesis of uveitic glaucoma. J Curr Glaucoma Pract. 2018;12:125-38.
  3. Lee JW, Chan JCh, Qing L, Lai JS. Early postoperative results and complications of using the EX-PRESS shunt in uncontrolled uveitic glaucoma: a case series of preliminary results. J Curr Glaucoma Pract. 2014;8:20-4.
  4. Mermoud A. Ex-PRESS implant. Br J Ophthalmol. 2005;89:396-97.
  5. Mabray MC, Uzelac A, Talbott JF, Lin SC, Gean AD. Ex-PRESS glaucoma filter: an MRI compatible metallic orbital foreign body imaged at 1.5 and 3T. Clin Radiol. 2015;70:e28-34.